Instrument Functions
R&S
®
UPP
443
User Manual 1411.1055.32 ─ 10
Remote command:
View Mode
For defining how the channel-status information should appear.
"Text"
The bit fields are displayed both as binary values (MSB first) and in
plain text.
"Binary"
The bit fields are displayed only as binary values (MSB first). This
reduces the space required by the "Dig Analyzer Protocol" window.
Remote command:
5.31.2
Channel-Status Information Display
The R&S
UPP decodes the first five bytes of each channel and displays the current
information from the individual bit fields in a readable form for both channels in the "Dig
Analyzer Protocol" window.
Digital Audio instrument: Channel information is always decoded and displayed for
both channels, regardless of whether only one or both audio channels are being mea-
sured.
HDMI instrument: The decoding and display of the channel information is always done
for one channel.
There are two different formats, defined by the value of the first bit:
●
The format for the consumer area (Consumer format); bit #0 = 0
●
The format for the professional area (Professional format); bit #0 = 1
In the Automatic display mode the correct format (Consumer or Professional) is set for
each channel according to its format bit, so that even data streams with a different for-
mat in channels 1 and 2 can be displayed.
Protocol Analysis
Summary of Contents for R&S UPP
Page 1: ...R S UPP Audio Analyzer User Manual User Manual Version 10 1411105532 ÅP ...
Page 34: ...Contents R S UPP 18 User Manual 1411 1055 32 10 ...
Page 630: ...Instrument Functions R S UPP 614 User Manual 1411 1055 32 10 Format ...
Page 631: ...Instrument Functions R S UPP 615 User Manual 1411 1055 32 10 Format ...