Instrument Functions
R&S
®
UPP
349
User Manual 1411.1055.32 ─ 10
Remote command:
5.18
Time-Controlled Measured value Recording
In time-controlled measured value recording, the estimated total recording time is
derived from the product of the time interval per measurement and the number of mea-
sured value acquisitions. The actual duration of the measured value recording may be
considerably longer in the case of the time tick start condition if the value entered for
the time tick is shorter than the required measurement time.
Time
Used for entering the time grid in which it is intended measurements should be started
("time tick") or measured values should be read ("time chart").
When the start condition is "Time Tick" the measurement has priority over the start of a
new measurement. If the time tick is longer than the measurement time, the system
waits for the next time tick after each single measurement. During this waiting time no
measurement is performed. If the time tick is shorter than the measurement time, any
time ticks occurring during a running measurement will be ignored. This means that
measurements will be started at time intervals corresponding to an integer multiple (≥1)
of the selected time tick.
When the start condition is "Time Chart" (not available in the multichannel analyzers)
the measured value is read in the specified time grid, regardless of whether a new
measured value is present. If the chosen time grid (update rate) is longer than the
measurement time for the measurement function, then only end results are displayed.
If the time grid is shorter than the measurement time, intermediate results are dis-
played if available. If no intermediate results are yet available, the last valid results are
entered in the time chart again.
Remote command:
Points
For entering the number of measured value recordings.
Time-controlled measured value recording ends as soon as the number of measured
data items specified here are available.
Time-Controlled Measured value Recording
Summary of Contents for R&S UPP
Page 1: ...R S UPP Audio Analyzer User Manual User Manual Version 10 1411105532 ÅP ...
Page 34: ...Contents R S UPP 18 User Manual 1411 1055 32 10 ...
Page 630: ...Instrument Functions R S UPP 614 User Manual 1411 1055 32 10 Format ...
Page 631: ...Instrument Functions R S UPP 615 User Manual 1411 1055 32 10 Format ...