Instrument Functions
R&S
®
UPP
339
User Manual 1411.1055.32 ─ 10
Table 5-2: The following states are possible:
Off
Channel is deactivated; measured values are not recorded on this channel.
Single
Single measurement in progress
Cont
Continuous measurement is being performed
Terminated
(Single) measurement terminated
Stopped
Measurement has been terminated; continuous measurement has been paused.
Further messages about the states of a current measurement, e.g. underrange or over-
range information, can also be displayed. For more detailed information, see
ter 4.20, "Overview of Status Messages"
5.15.3.1
Continuous measurement
This is the standard operating mode of the measurement system, and it is set each
time the R&S
UPP is switched on. The R&S
UPP measures all activated measure-
ment types continuously until one of the following events occurs:
START
[START ] terminates the current measurement immediately, resets the MIN/MAX indi-
cator, the MIN/MAX values, the limit violations of the measurement displays, and cau-
ses continuous measurement to be restarted.
Furthermore, starting or restarting a measurement also causes certain generator func-
tions to restart:
●
The sine-burst burst signal is reset, that is, it starts with the burst phase or burst on
delay.
●
The Play function starts again at the first sample in the WAV file.
●
The Arbitrary function also starts again at the beginning.
Remote command:
SINGLE
[SINGLE ] switches to single measurement. Each measurement type first completes
the measurement that has already been started; when all measurement types have
been completed, the measurement system is in the "Term" (terminated) state. Continu-
ous measurement can be reactivated by pressing [START] or [STOP/CONT].
Starting Measurements
Summary of Contents for R&S UPP
Page 1: ...R S UPP Audio Analyzer User Manual User Manual Version 10 1411105532 ÅP ...
Page 34: ...Contents R S UPP 18 User Manual 1411 1055 32 10 ...
Page 630: ...Instrument Functions R S UPP 614 User Manual 1411 1055 32 10 Format ...
Page 631: ...Instrument Functions R S UPP 615 User Manual 1411 1055 32 10 Format ...