Instrument Functions
R&S
®
UPP
198
User Manual 1411.1055.32 ─ 10
Impedance
From serial numbers 120100, 140100, 180100 and higher, an output impedance of
either 25
Ω
or 600
Ω
can be set in this field (previously, the impedance was perma-
nently set at 25
Ω
).
If the eight-channel generator is used, the output impedance of the generator outputs
is set permanently to 25
Ω
.
Remote command:
Bandwidth
When you choose the universal generator you can set three different fixed frequency
ranges and one signal-dependent sampling frequency.
"22
kHz"
The maximum output frequency is 21.75
kHz. The generator DAC is
clocked at 48
kHz.
"40
kHz"
The maximum output frequency is 40
kHz. The generator DAC is
clocked at 96
kHz.
"80
kHz"
The maximum output frequency is 80
kHz. The generator DAC is
clocked at 192
kHz.
"Play Auto"
For the Play generator function only. The bandwidth is automatically
determined as a function of the sample rate entered in the WAV file.
This sample rate is likewise used for clocking the generator DAC.
Remote command:
Volt Range
Two different modes are available for generator level control.
"Auto"
The internal signal paths are optimally driven; the output voltage is
adjusted using the analog hardware.
Advantage:
Optimum noise and distortion values.
Configuring Analog Generator
Summary of Contents for R&S UPP
Page 1: ...R S UPP Audio Analyzer User Manual User Manual Version 10 1411105532 ÅP ...
Page 34: ...Contents R S UPP 18 User Manual 1411 1055 32 10 ...
Page 630: ...Instrument Functions R S UPP 614 User Manual 1411 1055 32 10 Format ...
Page 631: ...Instrument Functions R S UPP 615 User Manual 1411 1055 32 10 Format ...