Remote Control Commands
R&S
®
RTM3000
674
User Manual 1335.9090.02 ─ 08
Parameters:
<Polarity>
POSitive | NEGative
*RST:
POS
BUS<b>:MILStd:RESPonsetime:INFinite
<MaximumInfinite>
Suffix:
<b>
.
1..4
Parameters:
<MaximumInfinite>
ON | OFF
*RST:
ON
BUS<b>:MILStd:RESPonsetime:MAXimum
<MaximumTime>
Sets a value for the maximum response time.
Suffix:
<b>
.
1..2
Parameters:
<MaximumTime>
BUS<b>:MILStd:RESPonsetime:MINimum
<MinimumTime>
Sets the minimum response time.
Suffix:
<b>
.
1..4
Parameters:
<MinimumTime>
BUS<b>:MILStd:SOURce
<Source>
Sets the channel for the signal source for the MIL-STD-1553 analysis.
Suffix:
<b>
.
1..4
Parameters:
<Source>
CH1 | CH2 | CH3 | CH4
*RST:
CH1
BUS<b>:MILStd:THReshold:HIGH
<UpperLevel>
Sets the upper threshold level of the signal.
Suffix:
<b>
.
1..4
Serial Bus Analysis