Serial Bus Analysis
R&S
®
RTM3000
299
User Manual 1335.9090.02 ─ 08
Remote command:
Error
Select one or more error types as trigger condition.
Checksum ← Error
Checksum error. The checksum verifies the correct data transmission. It is the last byte
of the frame response. The checksum includes not only the data but also the protected
identifier (PID).
Remote command:
Parity ← Error
Parity error. Parity bits are the bits 6 and 7 of the identifier. They verify the correct
transmission of the identifier.
Remote command:
Synchronization ← Error
Error during synchronization.
Remote command:
Identifier condition
The identifier condition consists of the following settings:
●
Identifier value
●
Comparison
Identifier ← Identifier condition
Defines the identifier pattern in binary and hexadecimal format. To set an individual
binary bit or hex nibble (half byte), tap it and enter it via the on-screen keypad.
"Bin"
String containing the binary pattern with a maximum of 64
bits. Char-
acters 0, 1 and X are allowed.
"Hex"
String containing the hexadecimal pattern with a maximum of 8
bytes.
Characters 0 to F and X are allowed.
Remote command:
Compare ← Identifier condition
Sets the identifier comparison condition: If the identifier pattern contains at least one X
(don't care), you can trigger on values equal or not equal to the specified value. If the
pattern contains only 0 and 1, you can also trigger on a range greater than or lower
than the specified value.
Remote command: