Remote control commands
R&S
®
RTB2000
533
User Manual 1333.1611.02 ─ 11
LOGic<p>:TYPE
Selects the method to reduce the captured data of logical channels to a waveform with
lower sample rate.
Parameters:
<DecimationMode>
SAMPle | PDETect
SAMPle
Input data is acquired with a sample rate which is aligned to the
timebase (horizontal scale) and the record length.
PDETect
Peak Detect: the minimum and the maximum of n samples in a
sample interval are recorded as waveform points.
*RST:
SAMP
LOGic<p>:HYSTeresis
DIGital<m>:HYSTeresis
<Hysteresis>
Defines the size of the hysteresis to avoid the change of signal states due to noise.
The setting applys to the logic pod to which the indicated logic channel belongs.
Suffix:
<m>
.
0..15
Selects the logic channel.
<p>
1..2
Selects the logic pod.
Parameters:
<Hysteresis>
SMALl | MEDium | LARGe
Manual operation:
See
DIGital<m>:SIZE
<Size>
Sets the vertical size of the indicated digital channel.
Suffix:
<m>
.
0..15
Number of the logic channel
Parameters:
<Size>
Specifies the number of divisions per logic channel.
Range:
0.2 to 8
Increment: 0.1
*RST:
0.3
Default unit: DIV
DIGital<m>:POSition
<Position>
Sets the vertical position of the indicated vertical channel.
Mixed signal option (option R&S
RTB-B1)