Remote Control Commands
R&S
®
NGL200/NGM200
159
User Manual 1178.8736.02 ─ 09
Parameters for setting and query:
<arg0>
1 | 2
Channel selection for the digital output source.
Example:
DIO:OUTP 1, 1
Enables channel 1 as the digital output source.
DIO:OUTPut:SIGNal
<arg0>, <arg1>
DIO:OUTPut:SIGNal?
<arg0>
Select digital output signal type.
Parameters:
<arg1>
CONStant | PULSe
CONStant
An constant level trigger signal is sent out
PULSe
An output pulse of 100 ms trigger signal is sent out
Parameters for setting and query:
<arg0>
Channel number.
Example:
DIO:OUTP:SIGN? 1
Returns signal type at digital output for channel 1.
7.7.4
Battery Simulation
Available only with R&S NGM power supply series.
The
BATT
subsystem contains the commands for configuring the battery simulator and
battery model function for the output channels.
......................................................................................... 160
BATTery:SIMulator:CAPacity:LIMit
................................................................................... 160
.........................................................................................160
BATTery:SIMulator:CURRent:LIMit?
.................................................................................160
BATTery:SIMulator:CURRent:LIMit:EOC
...........................................................................161
BATTery:SIMulator:CURRent:LIMit:EOD
...........................................................................161
BATTery:SIMulator:CURRent:LIMit:REGular
..................................................................... 161
......................................................................................161
........................................................................................162
................................................................................................162
.................................................................................... 162
.......................................................................................162
........................................................................................... 163
BATTery:MODel:CURRent:LIMit:EOC
.............................................................................. 163