R&S FSP
Remote Control – Description of Commands
GPIB Commands of HP Models 856xE, 8566A/B, 8568A/B and 8594E
6.278
Operating Manual 1164.4556.12 - 06
6.23.7
Model-Dependent Default Settings
If the GPIB language is switched over to an 85xx model, the GPIB address will automatically be switched
over to 18 provided that the default address of the R&S FSP (20) is still set. If a different value is set, this
value will be maintained. Upon return to SCPI, this address will remain unchanged.
The following table shows the default settings obtained after a change of the GPIB language and for the
commands IP, KST and RESET:
6.23.8
Data Output Formats
In the case of the SCPI and IEEE488.2 standards, the output formats for numerical data are flexible to a
large extent. The output format for the HP units, by contrast, is accurately defined with respect to the
number of digits. The memory areas for reading instrument data have therefore been adapted accord-
ingly in the remote-control programs for instruments of this series.
Therefore, in response to a query, the R&S FSP returns data of the same structure as that used by the
original instruments; this applies in particular to the number of characters returned.
Two formats are currently supported when trace data is output: Display Units (command O1) and physi-
cal values (command O2, O3 or TDF P). As to the "Display Units" format, the level data of the R&S FSP
is converted to match the value range and the resolution of the 8566/8568 series. Upon transition to the
Model
# of Trace Points
Start Freq.
Stop Freq.
Ref Level
Input Coupling
8566A/B
1001
2 GHz
22 GHz
0 dBm
AC
8568A/B
1001
0 Hz
1.5 GHz
0 dBm
AC
8560E
601
0 Hz
2.9 GHz
0 dBm
AC
8561E
601
0 Hz
6.5 GHz
0 dBm
AC
8562E
601
0 Hz
13.2 GHz
0 dBm
AC
8563E
601
0 Hz
26.5 GHz
0 dBm
AC
8564E
601
0 Hz
40 GHz
0 dBm
AC
8565E
601
0 Hz
50 GHz
0 dBm
AC
8594E
401
0 Hz
3 GHz
0 dBm
AC
Notes regarding the set stop frequency:
• The stop frequency given in the table may be limited to the corresponding
frequency range of the R&S FSUP.
• Command LF sets the stop frequency for 8566A/B to a maximum value of 2
GHz.
Note regarding the number of test points (trace points):
• The number of trace points is switched over only upon transition to the REMOTE
state.
Summary of Contents for R&S FSP Series
Page 1: ...R S FSP Spectrum Analyzer Operating Manual 1164 4556 12 06 Test Measurement Operating Manual ...
Page 24: ...R S FSP Putting into Operation 1 2 Operating Manual 1164 4556 12 06 ...
Page 72: ...R S FSP Manual Operation 3 2 Operating Manual 1164 4556 12 06 ...
Page 793: ...R S FSP Index Operating Manual 1164 4556 12 06 4 11 ...
Page 794: ...R S FSP 4 12 Operating Manual 1164 4556 12 06 ...
Page 795: ...Operating Manual 1164 4556 12 06 4 13 R S FSP ...
Page 796: ...R S FSP 4 14 Operating Manual 1164 4556 12 06 ...