Operating Manual 1164.4556.12 - 06
2.17
R&S FSP
Getting Started
Noise Measurements
2.4.2
Measurement of Noise Power within a Transmission Channel
Noise in any bandwidth can be measured with the channel power measurement
functions. Thus the noise power in a communication channel can be determined, for
example. If the noise spectrum within the channel bandwidth is flat, the noise marker
from the previous example can be used to determine the noise power in the channel
by considering the channel bandwidth. If, however, phase noise and noise that nor-
mally increases towards the carrier is dominant in the channel to be measured, or if
there are discrete spurious signals in the channel, the channel power measurement
method must be used to obtain correct measurement results.
2.4.2.1
Measurement Example – Measuring the intrinsic noise of the R&S FSP at 1
GHz in a 1.23 MHz channel bandwidth with the channel power function
Test setup:
The RF input of the R&S FSP remains open-circuited or is terminated with 50
Ω
.
Measurement with the R&S FSP:
1. Set the R&S FSP to its default state.
➢
Press the
PRESET
key.
The R&S FSP is in its default state.
2. Set the center frequency to 1 GHz and the span to 2 MHz.
➢
Press the
FREQ
key and enter
1 GHz.
➢
Press the
SPAN
key and enter
2 MHz
.
3. To obtain maximum sensitivity, set RF attenuation on the R&S FSP to 0 dB.
➢
Press the
AMPT
key.
➢
Press the
RF ATTEN MANUAL
softkey and enter
0 dB
.
4. Switch on and configure the channel power measurement.
➢
Press the
MEAS
key.
➢
Press the
CHAN PWR ACP
softkey.
The R&S FSP activates the channel or adjacent channel power measurement
according to the currently set configuration.
➢
Press the
CP/ACP CONFIG
!
softkey.
The R&S FSP enters the submenu for configuring the channel.
➢
Press the
CHANNEL BANDWIDTH
softkey and enter
1.23 MHz
.
The R&S FSP displays the 1.23 MHz channel as two vertical lines which are
symmetrical to the center frequency.
➢
Press the
PREV
key.
The R&S FSP returns to the main menu for channel and adjacent channel
power measurement.
➢
Press the
ADJUST SETTINGS
softkey.
The settings for the frequency span, the bandwidth (RBW and VBW) and the
detector are automatically set to the optimum values required for the
measurement.
Summary of Contents for R&S FSP Series
Page 1: ...R S FSP Spectrum Analyzer Operating Manual 1164 4556 12 06 Test Measurement Operating Manual ...
Page 24: ...R S FSP Putting into Operation 1 2 Operating Manual 1164 4556 12 06 ...
Page 72: ...R S FSP Manual Operation 3 2 Operating Manual 1164 4556 12 06 ...
Page 793: ...R S FSP Index Operating Manual 1164 4556 12 06 4 11 ...
Page 794: ...R S FSP 4 12 Operating Manual 1164 4556 12 06 ...
Page 795: ...Operating Manual 1164 4556 12 06 4 13 R S FSP ...
Page 796: ...R S FSP 4 14 Operating Manual 1164 4556 12 06 ...