Basic Settings
The
SERVICE
softkey opens a submenu for selection of the service function.
The
INPUT RF
and
INPUT CAL
softkeys are mutually exclusive selection switches.
Only one switch can be active at any one time.
General Service Functions
INPUT RF
The
INPUT RF
softkey switches the input of the R&S FSP to the input connector
(normal position).
After
PRESET
,
RECALL
or R&S FSP power on, the
INPUT RF
is always selected.
Remote command:
DIAG:SERV:INP RF
INPUT CAL
The
INPUT CAL
softkey switches the RF input of the R&S FSP to the internal cali-
bration source (128 MHz) and activates the data entry of the output level of the cali-
bration source. Possible values are 0 dB and –30 dB.
Remote command:
DIAG:SERV:INP CAL;
DIAG:SERV:INP:CSO 0 DBM
ENTER
PASSWORD
The
ENTER PASSWORD
softkey allows the entry of a password.
The R&S FSP contains a variety of service functions which, if incorrectly used, can
affect correct operation of the R&S FSP. These functions are normally not accessi-
ble and are only usable after the entry of a password (see instrument service man-
ual).
Remote command:
SYST:PASS "Password"
CAL GEN 128
MHZ
The
CAL GEN 128 MHZ
softkey selects a sinusoidal signal at 128 MHz as output
signal for the internal calibration source. The internal pulse generator will be
switched off.
Remote command:
DIAG:SERV:INP CAL
DIAG:SERV:INP:PULS OFF
CAL GEN
COMB PULSE
This softkey switches the internal pulse generator on and allows the pulse frequency
to be entered.
With option R&S FSP-B15, available pulse frequencies are 10 kHz and 62.5 kHz.
For model FSP40, the pulse frequency 640 MHz is selected.
Remote command:
DIAG:SERV:INP:PULS ON;
DIAG:SERV:INP:PULS:PRAT <value>
The softkey is only available if the optional Broadband Calibration Source
R&S FSP-B15 is fitted.
The softkey is only available for model FSP40 or if the optional Broadband Calibra-
tion Source R&S FSP-B15 is fitted.
Summary of Contents for R&S FSP Series
Page 1: ...R S FSP Spectrum Analyzer Operating Manual 1164 4556 12 06 Test Measurement Operating Manual ...
Page 24: ...R S FSP Putting into Operation 1 2 Operating Manual 1164 4556 12 06 ...
Page 72: ...R S FSP Manual Operation 3 2 Operating Manual 1164 4556 12 06 ...
Page 793: ...R S FSP Index Operating Manual 1164 4556 12 06 4 11 ...
Page 794: ...R S FSP 4 12 Operating Manual 1164 4556 12 06 ...
Page 795: ...Operating Manual 1164 4556 12 06 4 13 R S FSP ...
Page 796: ...R S FSP 4 14 Operating Manual 1164 4556 12 06 ...