GATED
TRIGGER
Statistic measurements on pulsed signals can be done using the
GATED TRIGGER
softkey. An external frame trigger is required as a time (frame) reference.
The gate ranges define the part of the I/Q capture data taken into account for the
statistics calculation.
These ranges are defined relative to a reference point T=0. The gate interval is
repeated every period time until the end of the I/Q capture buffer.
The reference point T=0 is defined by the external trigger event and the instrument's
trigger offset.
GATED TRIGGER
activates the gating for statistics functions. The trigger source is
changed to EXTERN if this function is switched on.
[
CCDF ON /OFF
]
Switch on measurement of the complementary cumulative
distribution function. The R&S FSP switches to zero span
mode. The power of the signal and the CCDF is calculated
for the number of samples selected. With the CCDF func-
tion sample detector and video bandwidth are set auto-
matically.
[NO OF SAMPLES:
10000]
Set the number of measurement samples to 10000.
[SINGLE MEAS]
Start the measurement sequence. At the end the resulting
trace will display the CCDF for the measured 10000 sam-
ples.
Summary of Contents for R&S FSP Series
Page 1: ...R S FSP Spectrum Analyzer Operating Manual 1164 4556 12 06 Test Measurement Operating Manual ...
Page 24: ...R S FSP Putting into Operation 1 2 Operating Manual 1164 4556 12 06 ...
Page 72: ...R S FSP Manual Operation 3 2 Operating Manual 1164 4556 12 06 ...
Page 793: ...R S FSP Index Operating Manual 1164 4556 12 06 4 11 ...
Page 794: ...R S FSP 4 12 Operating Manual 1164 4556 12 06 ...
Page 795: ...Operating Manual 1164 4556 12 06 4 13 R S FSP ...
Page 796: ...R S FSP 4 14 Operating Manual 1164 4556 12 06 ...