Command Reference
R&S
®
CMW-KN5xx
101
User Manual 1176.7690.02 ─ 05
<OBW>
Occupied bandwidth
Range:
0 MHz to 40 MHz
Default unit: Hz
<TXpowerMin>
Minimum total TX power in the subframe
Range:
-100 dBm to 55 dBm
Default unit: dBm
<TXpowerMax>
Maximum total TX power in the subframe
Range:
-100 dBm to 55 dBm
Default unit: dBm
Example:
See
Performing Single-Shot Measurements
Usage:
Query only
Firmware/Software:
V3.0.20
For additional information concerning syntax elements and returned values refer to
Conventions and General Information
.
FETCh:LTE:MEAS<i>:ENB:MEValuation:SEMask:MARGin?
READ:LTE:MEAS<i>:ENB:MEValuation:SEMask:MARGin?
Returns spectrum emission mask margin results. A negative margin indicates that the
trace is located above the limit line, i.e. the limit is exceeded.
Results are provided for the current, average and maximum traces. For each trace 20
values related to the negative (Neg) and positive (Pos) offset frequencies of emission
mask areas 1 to 10 are provided. For inactive areas NCAP is returned.
The number to the left of each result parameter is provided for easy identification of the
parameter position within the result array.
Return values:
<1_Reliability>
<2_OutOfTol>
Out of tolerance result, i.e. percentage of measurement inter-
vals of the statistic count for spectrum emission measurements
exceeding the specified spectrum emission mask limits.
Range:
0 % to 100 %
Default unit: %
<3_CurrNeg1> ...
<12_CurrNeg10>
<13_CurrPos1> ...
<22_CurrPos10>
Margin results for current trace
Range:
-160 dB to 160 dB
Default unit: dB
<23_AvgNeg1> ...
<32_AvgNeg10>
<33_AvgPos1> ...
<42_AvgPos10>
Margin results for current trace
Range:
-160 dB to 160 dB
Default unit: dB