NB-IoT Signaling
R&S
®
CMW-KM300/-KS300
87
User Manual 1178.5689.02 ─ 06
Figure 2-52: Incoming SMS parameters
Select File
Selects a file from the system drive folder
@USERDATA\sms\NBIOT\Received
.
Incoming messages are stored there with the file extension
.sms
.
Only messages received in the current session are available. The files are deleted dur-
ing startup.
Remote command:
CONFigure:NIOT:SIGN<i>:SMS:INComing:FILE
CONFigure:NIOT:SIGN<i>:SMS:INComing:FILE:INFO?
Data Coding / Character Set
Indicates whether the last received message is a 7-bit ASCII message, an 8-bit binary
message or a 16-bit Unicode message.
Remote command:
SENSe:NIOT:SIGN<i>:SMS:INComing:INFO:DCODing?
Message Text / Message Length
Show the text and length of the last received SMS message.
Remote command:
SENSe:NIOT:SIGN<i>:SMS:INComing:INFO:MTEXt?
SENSe:NIOT:SIGN<i>:SMS:INComing:INFO:MLENgth?
Clear Message Text
The button resets all parameters related to a received message.
The message information is deleted. The "message read" flag is set to true.
Remote command:
SENSe:NIOT:SIGN<i>:SMS:INFO:LRMessage:RFLag?
CLEan:NIOT:SIGN<i>:SMS:INComing:INFO:MTEXt
2.3.13
Message Monitoring Settings
Messages exchanged between the NB-IoT signaling application and the UE can be
monitored. For this purpose, the messages are sent to an external PC.