NB-IoT Multi-Evaluation Measurement
R&S
®
CMW-KM300/-KS300
236
User Manual 1178.5689.02 ─ 06
EVM Excl. Periods Leading/Lagging < Modulation
The settings allow you to exclude the first (leading) and the last (lagging) SC-FDMA
symbol of each NPUSCH transmission from the modulation measurements.
Remote command:
Select ACLR < ACLR < Spectrum
Specifies which adjacent channels are evaluated: GSM channels and/or UTRA chan-
nels.
Remote command:
CONFigure:NIOT:MEAS<i>:MEValuation:SPECtrum:ACLR:ENABle
Time Mask < Dynamics < Power
Displays the type of time mask used for power dynamics measurements.
The general on/off time mask is defined in 3GPP TS 36.521, section 6.3.4F.
See also
Chapter 3.3.6.8, "Power Dynamics Limits"
Enable < List Mode
The list mode can only be enabled via remote control command. When the list mode
has been enabled, the checkbox allows you to disable the list mode.
You can disable the list mode also by changing the measurement mode, see
Remote command:
CONFigure:NIOT:MEAS<i>:MEValuation:LIST
Offline Segment Nr. < List Mode
Selects the list mode segment to be displayed in the measurement diagram. To select
a segment number, the list mode must be enabled.
Option R&S CMW-KM012 is required.
Remote command:
CONFigure:NIOT:MEAS<i>:MEValuation:LIST:OSINdex
3.3.5
Trigger Settings
Access: "Config" hotkey > "Trigger" section.
The trigger settings configure the trigger system for the NB-IoT multi-evaluation mea-
surement.