7.6.1
Moving the Elevation Positioner
The elevation positioner is the antenna arm. It can rotate up to
-20°
to the front and the
following maximum angle to the rear:
●
If you set the NCD controller manually, the maximum rotation to the rear is limited
to
+160°
.
●
If you use the R&S
AMS32 software for setting the angle, the elevation arm can
rotate down to
+165°
to the rear. Before making this setting, make sure that you
have removed the turntable's crank. See
.
Prerequisites:
●
The chamber is set up as described in
Chapter 6, "Installation and Commission-
●
The chamber is activated; see
Chapter 7.1, "Activating the Chamber"
●
The NCD controller is activated; see
To move the elevation positioner arm
1.
NOTICE!
Risk of antenna collision with the turntable's crank. If the antenna arm
moves below 160° elevation (maximum is 165°, see below), the antenna mounted
on the arm can collide with the turntable's crank. Such a collision typically destroys
the antenna.
Make sure that the turntable's crank is removed; see
.
2. Close the chamber door as described in
Chapter 7.3.4, "Closing the Door"
Closing the door releases the lower interlock (
); the positioners are no
longer prevented from moving.
Release of the interlock is also indicated in the display of the NCD controller, i.e.
the interlock symbol disappears; see
3. Tap the control element
"New Angle AB1"
).
An on-screen keypad is displayed.
4. Enter the target elevation angle for the antenna positioner arm.
5. Tap "OK" to confirm the entry.
Operating the Positioning System