Functions
R&S
®
OSP
185
User Manual 1178.7100.02 ─ 05
Figure 5-30: Path definition information dialog
To close this dialog, click the "Back" button .
Manage path selection:
Only available, if you have selected at least one relay or output channel, as in
Figure 5-31: Path Switching dialog with existing paths and option for saving a new path
With selected items, the selection indicator is active, see
Now the list of paths offers a function bar, labeled
"Manage path selection:"
, that pro-
vides the following functions:
The button
"Save As New Path"
defines a new path based on the current selection of
relays and output channels. The firmware saves the switching state of each selected
relay and output channel into a list that represents this new path.
For an example of how to define and save a path, see
"Creating a path configuration"
Note that the relays and output channels can be selected in different modules of one
switch unit (frame) and in different frames of an
setup.
For example, if you have selected only relay "K2" in module "M01" in frame "F01", and
the state of relay "K2" is "activated" ("01"), the path definition is "
(@F01M01(0102))
".
The syntax in this definition is used as a SCPI parameter for the remote control com-
Path Switching