Remote Control - Commands
NRP2
234
User Manual 1173.9140.02 ─ 07
Parameters:
<auto>
OFF | ONCE
*RST:
OFF
CALCulate<[1]..8>:RELative:POWer[:MAGNitude]
<value>
Has the same direct effect as
CALC:REL
on the reference value for measured values
that share the unit of a power.
Parameters:
<value>
float_value, units: DBM | W
Range:
1e-18..1e18 W | -150..210 DBM
*RST:
0 DBM
Default unit: DBM
CALCulate<[1]..8>:RELative:RATio[:MAGNitude]
<value>
Has the same direct effect as
CALC:REL
on the reference value for measured values
that share the unit of a power ratio.
Parameters:
<value>
float_value, units: DB | PCT
Range:
-200..200 DB | 1e-18..1e22 PCT
*RST:
0 DB
Default unit: DB
CALCulate<[1]..8>:RELative:STATe
<state>
Determines whether a reference value is used. If this command is called with
ON
, all
results of the calculate block are divided by the reference value set with
CALCulate[1..8]:RELative[:MAGNitude]
.
Parameters:
<state>
ON | OFF
ON
all results of the calculate block are divided by the reference
value set with
CALCulate<[1]..8>:RELative[:MAGNitude]
.
OFF
a reference value is not used.
*RST:
OFF
CALCulate<[1]..8>:SDEViation:DATA?
Queries the standard deviation
σ
of all measured values of the calculate block. The
standard deviation is calculated together with the mean value and reset. The following
formula applies:
CALCulate (Configuration of Calculate Blocks)