SCPI Commands HMF series
Remote Control
69
Command Reference
SCPI Programmers Manual
TRIGger:SOURce?
Queries the trigger source.
Return values:
IMM | EXT
TRIgger:SLOPe {POSitive | NEGative}
Defines the slope of the trigger input.
Parameters:
<Slope>
POSitive | NEGative
POSitive
:
Rising edge
NEGative
:
Falling edge
*RST:
POS
TRIGger:SLOPe?
Queries the slope of the trigger input.
Return values:
POS | NEG
OUTPut:TRIGger {OFF | ON | 0 | 1}
Activates or deactivates the trigger output (TTL - front BNC connector).
Parameters:
<State>
ON | 1
:
The trigger output will be activated.
OFF | 0
:
The trigger output will be disabled.
*RST: OFF | 0
OUTPut:TRIGger?
Queries the state of the trigger output.
Return values:
ON
:
The trigger output is activated.
OFF
:
The trigger output is disabled.
OUTPut:TRIGger:SLOPe {POSitive | NEGative}
Defines the slope of the trigger output.
Parameters:
<Slope>
POSitive | NEGative
POSitive
:
Rising edge
NEGative
:
Falling edge
*RST:
POS