Remote Commands
R&S
®
FSW
865
User Manual 1173.9411.02 ─ 19
Parameters:
<ConnType>
RF
RF input connector
AIQI
Analog Baseband I connector
*RST:
RF
Example:
INP:CONN:AIQI
Selects the analog baseband input.
Usage:
SCPI confirmed
Manual operation:
See
INPut:COUPling
<CouplingType>
This command selects the coupling type of the RF input.
Parameters:
<CouplingType>
AC
AC coupling
DC
DC coupling
*RST:
AC
Example:
INP:COUP DC
Usage:
SCPI confirmed
Manual operation:
See
INPut:FILTer:HPASs[:STATe]
<State>
Activates an additional internal high-pass filter for RF input signals from 1
GHz to
3
GHz. This filter is used to remove the harmonics of the R&S
FSW in order to mea-
sure the harmonics for a DUT, for example.
This function requires option R&S
FSW-B13.
(Note: for RF input signals outside the specified range, the high-pass filter has no
effect. For signals with a frequency of approximately 4 GHz upwards, the harmonics
are suppressed sufficiently by the YIG filter.)
Parameters:
<State>
ON | OFF
*RST:
OFF
Usage:
SCPI confirmed
Manual operation:
See
Setting Basic Measurement Parameters