Remote Commands
R&S
®
FSW
860
User Manual 1173.9411.02 ─ 19
Parameters:
<OutputType>
DEVice
Sends a trigger signal when the R&S
FSW has triggered inter-
nally.
TARMed
Sends a trigger signal when the trigger is armed and ready for
an external trigger event.
UDEFined
Sends a user defined trigger signal. For more information see
*RST:
DEVice
Manual operation:
See
OUTPut:TRIGger<port>:PULSe:IMMediate
This command generates a pulse at the trigger output.
Suffix:
<port>
.
Selects the trigger port to which the output is sent.
2 = trigger port 2 (front)
3 = trigger port 3 (rear)
Usage:
Event
Manual operation:
See
OUTPut:TRIGger<port>:PULSe:LENGth
<Length>
This command defines the length of the pulse generated at the trigger output.
Suffix:
<port>
.
Selects the trigger port to which the output is sent.
2 = trigger port 2 (front)
3 = trigger port 3 (rear)
Parameters:
<Length>
Pulse length in seconds.
Manual operation:
See
11.7.5 Adjusting Settings Automatically
The commands required to adjust settings automatically in a remote environment are
described here. The tasks for manual operation are described in
Setting Basic Measurement Parameters