![Rohde & Schwarz FSH13 Operating Manual Download Page 338](http://html.mh-extra.com/html/rohde-and-schwarz/fsh13/fsh13_operating-manual_1477832338.webp)
R&S FSH
Digital Modulation Analyzer
Measurements on LTE Signals
Operating Manual 1173.6275.12 - 30
323
9.8.6.5 Selecting the Synchronization Signal
The synchronization signal selects the way the R&S FSH synchronizes to the LTE
signal. By default, the R&S FSH automatically determines the type of synchronization
signal to use.
Alternatively, you can select the synchroniztaion signal manually. You can either
synchronize to the PSYNC or SSYNC signals or synchronize to the reference signal.
► Press the "Signal Settings" softkey.
► Select the PSYNC/SSYNC menu item.
The R&S FSH synchronizes to the PSYNC or SSYNC.
► Select the "Reference Signal" menu item.
The R&S FSH synchronizes to the reference signal. For more information see
"
9.8.6.6 Selecting the MIMO Configuration
You can perform measurements on equipment with 1, 2 or 4 transmission antennas.
For measurements on base stations with one or two transmit antennas it is possible to
perform detailed measurements on single antennas via cable connection.
Because the reference signals of the different antennas are orthogonal, it is possible to
determine and display their power and EVM during over-the-air measurements.
► Press the MEAS key.
► Press the "Antenna Settings" softkey.
► Select the menu item that corresponds to the setup of the equipment you are
measuring.
If you want to measure a specific antenna, select the antenna number. Note that
selecting a specific antenna in multiple antenna systems is available only for 2-antenna
systems.
If you want to measure all antennas of the system, select the "Over-the-air" menu item.
9.8.6.7 Selecting the Unit of the Carrier Frequency Error
The absolute frequency error is the sum of the frequency error of the R&S FSH and
that of the device under test. If the frequency error is more than 1 kHz, the R&S FSH is
not able to synchronize with the signal. If possible, you should synchronize the receiver
and the transmitter.
The carrier frequency error can have the unit Hz or ppm.
► Press the MEAS key.
► Press the "Display Settings" softkey.
► Select the "Hz" or "ppm" menu item.
The R&S FSH shows the carrier frequency error in the unit you have selected.