R&S FSH
Digital Modulation Analyzer
Measurements on TD-SCDMA Signals
Operating Manual 1173.6275.12 - 30
306
9.7.6.4 Defining the Switching Point
A TD-SCDMA subframe contains two switching points where the signal switches from
downlink to uplink or vice versa. The first switching point is fix after the guard period of
the special time slot, the second switching point is arbitrary and is between one of the
last six time slots. The switch point is thus a number between 0 and 6.
► Press the MEAS key.
► Press the "Signal Settings" softkey.
► Select the "Set Switch Point Manually" menu item.
The R&S FSH opens an input field to enter the switching point.
► Enter the number of the time slot after which the switching point occurs.
9.7.6.5 Selecting a Time Slot
In the several result result displays, the R&S FSH shows the power of a particular time
slot. By default, the R&S FSH shows the results for slot 0.
► Press the MEAS key.
► Press the "Display Settings" softkey.
► Select the "Slot Number" menu item.
The R&S FSH opens an input field to select the slot.
► Enter the number of the timeslot you want to analyze.
The R&S FSH adjusts the results accordingly.
Note that you can select only slots that are assigned to the downlink. The location of
downlink slots is defined by the switching point.
9.7.6.6 Changing the Code Power
By default, the application displays the absolute power of the code channels in the
Code Domain Power result display. Alternatively, you can display the power relative to
the RF channel power.
► Press the MEAS key.
► Press the "Power Settings" softkey.
► Select the "Relative to RF Channel Power" menu item.
The code domain power values are now relative to the RF channel power.