![Rohde & Schwarz EX-IQ-BOX User Manual Download Page 359](http://html1.mh-extra.com/html/rohde-and-schwarz/ex-iq-box/ex-iq-box_user-manual_1477982359.webp)
Remote Control Commands
R&S
®
EX-IQ-BOX
344
User Manual 1409.5570.32 ─ 05
[:SOURce<hw>]:EBOX:CPRI:TX|RX:GROup<user0>:PATTern
<pattern>
Queries the binary data pattern of an AxC and responses in binary format.
Enter the required pattern with the command, respecting the syntax as follows:
"#B0101010101010101,16"
#B
= binary representation
0101010101010101
= pattern
16
= pattern length
See also the example below for a complete command.
By default, all data pattern is set to zero. You can basically set up to 40 bits, but the
currently possible number depends on the signal length that is specified in
Parameters:
<pattern>
integer
Example:
EBOX:CPRI:TX:GRO:PATT "#B0101010101010101,16"
insert the pattern for the first signal, and assign the signal to AxC1
in the first group of the AxC allocation table,
Manual operation:
See
[:SOURce<hw>]:EBOX:CPRI:TX|RX:SOURce:GROup:CALC
Calculates the scheduling sequences of the groups.
Usage:
Event
Manual operation:
See
[:SOURce<hw>]:EBOX:CPRI:TX|RX:SOURce<ch>:GROup:COUNt
<Count>
Determines the number of groups for a signal. The grouping enables to achieve arbitrary
sample rates that are not necessarily integer multiples of the CPRI basic frame rate. Each
group defines an AxC configuration for a certain time, i.e. repetitions. Thus you can
change the AxC assignment over time by using more than one group with different set-
tings.
Parameters:
<Count>
integer
Range:
1 to 4
Increment: 1
*RST:
1
Example:
EBOX:CPRI:TX:SOUR:GRO:COUN 2
specify 2 groups for distribution of the first signal in the CPRI
frame.
Manual operation:
See
CPRI Remote Control Commands