![Rohde & Schwarz EX-IQ-BOX User Manual Download Page 348](http://html1.mh-extra.com/html/rohde-and-schwarz/ex-iq-box/ex-iq-box_user-manual_1477982348.webp)
Remote Control Commands
R&S
®
EX-IQ-BOX
333
User Manual 1409.5570.32 ─ 05
Parameters:
<Source>
PATTern | IQIN | ARB1 | ARB2 | ARB3 | ARB4 | STATic | PRBS
PATTern
Uses the internal pattern generator as signal source.
IQIN
An R&S instrument applies a digital baseband signal at DIQ IQ IN
1 connector of the R&S
EX-IQ-BOX.
ARB1...4
Selects one of the waveform memories with a loaded I/Q signal.
Notes:
This feature requires, that the R&S
EX-IQ-BOX is equipped with
the appropriate waveform memory option.
A conflict arises, if no signal is loaded in the memory, or is not
activated.
The Multi Waveform options support simultaneous playback of up
to four signals. For information on the available options refer to
chapter 3.2.2.3, "Waveform Memory, Multi Waveform Playback
and Recording Memory "
STATic
Fills the complete CPRI frame with a static pattern for debugging
purposes. This pattern is transmitted as it is, without scaling,
rounding or interleaving.
PRBS
Generates a PRBS pattern.
*RST:
IQIN
Example:
SOUR1:EBOX:CPRI:TX:SIGN:SOUR ARB1
selects the signal of the first waveform memory as signal source.
Manual operation:
See
[:SOURce<hw>]:EBOX:CPRI:TX|RX:APPLy
Assigns the downlink/uplink settings in order to become effective.
Example:
SOUR1:EBOX:CPRI:TX:APPL
accept the settings.
Usage:
Event
Manual operation:
See
[:SOURce<hw>]:EBOX:CPRI:TX|RX:AXC:COUNt?
Queries the number of used AxCs.