![Rohde & Schwarz EX-IQ-BOX User Manual Download Page 307](http://html1.mh-extra.com/html/rohde-and-schwarz/ex-iq-box/ex-iq-box_user-manual_1477982307.webp)
Remote Control Commands
R&S
®
EX-IQ-BOX
292
User Manual 1409.5570.32 ─ 05
Example:
SOUR1:EBOX:CPRI:CM:ETH:BRAT?
query the current bit rate of fast C&M.
Response:
122.88
the current bit rate is 122.88 Mbit/s.
Usage:
Query only
Manual operation:
See
[:SOURce<hw>]:EBOX:CPRI:CM:ETH:COMMand
<Command>
This command enters a control command in fast C&M interactive mode.
Parameters:
<Command>
string
Example:
SOUR1:EBOX:CPRI:CM:ETH:COMM "test cmd"
transmit the test command for fast C&M control to the control
panel.
SOUR1:EBOX:CPRI:CM:ETH:EXEC
execute the test command.
Manual operation:
See
"Input Window, Command line, Execute"
[:SOURce<hw>]:EBOX:CPRI:CM:ETH:EXECute
The command sends the C&M data in fast C&M mode.
Example:
SOUR1:EBOX:CPRI:CM:ETH:EXEC
executes the control command, or command sequence of fast
C&M data.
Usage:
Event
Manual operation:
See
"Input Window, Command line, Execute"
[:SOURce<hw>]:EBOX:CPRI:CM:ETH:PPTR
<Ptr>
This command sets the CPRI Ethernet pointer. This setting determines the Fast C&M bit
rate, since this pointer represents the boundary between vendor data and Fast C&M Data
in the CPRI control block.
Parameters:
<Ptr>
20...63
Range:
20 to 63
Increment: 1
*RST:
20
Example:
SOUR1:EBOX:CPRI:CM:ETH:PPTR 25
set the ethernet pointer to 25.
Manual operation:
See
CPRI Remote Control Commands
Summary of Contents for EX-IQ-BOX
Page 147: ...Protocol Settings R S EX IQ BOX 132 User Manual 1409 5570 32 05 CPRI...