Remote Commands
R&S
®
EVSG1000
289
User Manual 1178.6227.02 ─ 06
GS_DEM_WIDE_BW?
GS_DEM_WIDE_BW
<Bandwidth>
Gets or sets the WIDE demodulator bandwidth in "ILS GP" mode.
Parameters:
<Bandwidth>
1KHZ | 3KHZ | 6KHZ | 10KHZ | 18KHZ | 25KHZ | 36KHZ |
50KHZ
Return values:
<State>
READY.
The command was executed successfully.
Manual operation:
See
GS_DEMFREQS_OFFSET_AUTOMAN?
GS_DEMFREQS_OFFSET_AUTOMAN
<Mode>
Gets or sets the mode of the demodulator frequency offset in "ILS GP" mode.
Parameters:
<Mode>
AUTO
Sets the demodulator frequenecy offset automatically.
MANUAL
Sets the demodulator frequency offset manually.
Return values:
<State>
READY.
The command was executed successfully.
Manual operation:
See
"CRS/CLR Carr (Autotune function)"
GS_DEMFREQS_OFFSET_1F?
GS_DEMFREQS_OFFSET_1F
<Freq. Offset>
Gets or sets the demodulator 1F frequency offset in "ILS GP" mode.
Parameters:
<Freq. Offset>
Frequency offset
Default unit: kHz
Return values:
<State>
READY.
The command was executed successfully.
Manual operation:
See
GS_DEMFREQS_OFFSET_LOWERFREQ?
GS_DEMFREQS_OFFSET_LOWERFREQ
<Freq. Offset>
Gets or Sets the demodulator lower frequency offset in "ILS GP" mode.
ILS Localizer (LOC) and Glidepath (GP) Modes