Remote Commands
R&S
®
EVSF1000
189
User Manual 1178.6410.02 ─ 05
SETUP:ANALOG_OUT1
<Source>
Selects the source for Analog Out 1.
Parameters:
<Source>
CH1_DDM | CH2_DDM | CH1_BB_FULL | CH2_BB_FULL |
CH1_BB_AUDIO | CH2_BB_AUDIO
Return values:
<State>
READY.
The command was executed successfully.
SETUP:ANALOG_OUT2
<Source>
Selects the source for Analog Out 2.
Parameters:
<Source>
CH1_DDM | CH2_DDM | CH1_BB_FULL | CH2_BB_FULL |
CH1_BB_AUDIO | CH2_BB_AUDIO
Return values:
<State>
READY.
The command was executed successfully.
SETUP:AUDIOBW
<output volume>
This command specifies the bandwidth for audio output.
Parameters:
<output volume>
FULL | VOICE | ID_NOTCH | V_ID_NOTCH
FULL
Full bandwidth is output
VOICE
Voice frequencies (> 3
kHz) output
ID_NOTCH
ID frequency (1020 Hz) output
V_ID_NOTCH
Voice and ID frequencies output
Range:
0 to 100
*RST:
VOICE
Default unit: %
Return values:
<State>
READY.
The command was executed successfully.