Remote Control
R&S
®
ESRP
742
User Manual 1175.7445.02 ─ 08
CALCulate<n>:LIMit<k>:ESPectrum:PCLass<Class>:COUNt
<NoPowerClasses>
This command sets the number of power classes to be defined.
Suffix:
<n>
.
irrelevant
<k>
irrelevant
<Class>
irrelevant
Parameters:
<NoPowerClasses> 1 to 4
*RST:
1
Example:
CALC:LIM:ESP:PCL:COUN 2
Two power classes can be defined.
CALCulate<n>:LIMit<k>:ESPectrum:PCLass<Class>[:EXCLusive]
<State>
This command sets the power classes used in the spectrum emission mask measure-
ment. It is only possible to use power classes for which limits are defined. Also, either
only one power class at a time or all power classes together can be selected.
Suffix:
<n>
.
irrelevant
<k>
irrelevant
<Class>
1...4
the power class to be evaluated
Parameters:
<State>
ON | OFF
*RST:
OFF
Example:
CALC:LIM:ESP:PCL1 ON
Activates the first defined power class.
Manual operation:
See
See
CALCulate<n>:LIMit<k>:ESPectrum:PCLass<Class>:LIMit[:STATe]
<State>
This command defines which limits are evaluated in the measurement.
Suffix:
<n>
.
irrelevant
<k>
irrelevant
<Class>
1...4
the power class to be evaluated
Parameters:
<State>
ABSolute | RELative | AND | OR
Remote Commands in Spectrum Analyzer Mode