DIB-500 R4.1
Commissioning
Function tests DIB-500 R4.1
124
Installation and Operation Manual 90DIB500IM02 – 5.2
5.9.2.1
Checking operating statuses (via the NMC-511 FaultManager)
The procedure for checking the operating states of network components via the
NMC-511 FaultManager is described below.
Checking the operating status (via the NMC-511 FaultManager)
Preparation:
✓
The NMC-511 FaultManager application must have been started.
Carry out the following steps:
1. Navigate to the corresponding network component (network, hardware or software
component) via the Navigator of the NMC-511 FaultManager.
2. Check whether the respective network component is displayed in green in the Nav-
igator of the NMC-511 FaultManager.
➥
Provided the corresponding network component is displayed in red, you have to
perform a fault analysis; refer to the product documentation of the NMC-511
FaultManager.
✓
The function test has been completed.
5.9.2.2
Checking operating statuses (via the Service and Maintenance Tool, SMT)
The SMT (Service and Maintenance Tool) is a hardware component for checking the
(operating) statuses of the installed TIB/TOB.
The following (operating) statuses can be checked through the SMT:
|
Readiness for operation
|
Voltage supply
|
Readiness for operation of software components (n)
|
Temperature
|
Availability of the installed carriers
The procedure for performing a visual inspection with the aid of the SMT is described in
the following.
Visual Inspection with the Aid of the SMT
Preparation:
✓
The SMT and the service computer must already be connected, refer to section
5.7.2.3 on page 105.