TRIGger:TDSCdma:MEAS<i>:MEValuation:THReshold
<TriggerThres>
Defines the trigger threshold for power trigger sources.
Parameters:
<TriggerThres>
Range:
-50 dB to 0 dB
*RST:
-20 dB
Default unit: dB (full scale, i.e. relative to reference level minus
external attenuation)
Example:
See
Configuring the Trigger System
Firmware/Software:
V1.0.4.11
Manual operation:
See
TRIGger:TDSCdma:MEAS<i>:MEValuation:SDELay
<TrigSlotDelay>
Defines a delay time (integer number of timeslots) for all trigger sources except "Free
Run". The parameter delays the start of the measurement relative to the trigger event.
Parameters:
<TrigSlotDelay>
Range:
0 slots to 7 slots
*RST:
0 slots
Default unit: slots
Example:
See
Configuring the Trigger System
Firmware/Software:
V1.0.4.11
Manual operation:
See
TRIGger:TDSCdma:MEAS<i>:MEValuation:CDELay
<TrigChipDelay>
Defines a delay time (integer number of chips) for all trigger sources except "Free Run".
The parameter delays the start of the measurement relative to the trigger event.
Parameters:
<TrigChipDelay>
Range:
-432 chips to 432 chips
*RST:
0 chips
Default unit: chips
Firmware/Software:
V1.0.4.11
Manual operation:
See
TRIGger:TDSCdma:MEAS<i>:MEValuation:TOUT
<TriggerTimeout>
Selects the maximum time that the R&S
CMW will wait for a trigger event before it stops
the measurement in remote control mode or indicates a trigger timeout in manual oper-
ation mode. This setting has no influence on "Free Run" measurements.
Multi Evaluation Measurement Commands