Command Reference
R&S
®
CMW-KM750/-KM751
68
User Manual 1173.9670.02 ─ 05
CONFigure:TDSCdma:MEAS<i>:UESignal:SCODe
<ScrCode>
Selects the cell parameter ID identifying the cell and determining the scrambling code.
Parameters:
<ScrCode>
Range:
0 to 127
*RST:
0
Example:
See
Firmware/Software:
V1.0.4.11
Manual operation:
See
CONFigure:TDSCdma:MEAS<i>:UESignal:NUSers
<NumOfUser>
Selects the maximum number of users for one timeslot.
Parameters:
<NumOfUser>
US2 | US4 | US6 | US8 | US10 | US12 | US14 | US16
Maximum 2, 4,..., 16 users
*RST:
US16
Example:
See
Firmware/Software:
V1.0.4.11
Manual operation:
See
CONFigure:TDSCdma:MEAS<i>:UESignal:MTYPe
<ModType>
Selects the modulation type.
Parameters:
<ModType>
QPSK | EPSK | QAM
QPSK
: quadrature phase shift keying
EPSK
: eight phase shift keying (8PSK)
QAM
: quadrature amplitude modulation (16-QAM)
*RST:
QPSK
Example:
See
Firmware/Software:
V1.0.4.11
V2.1.10: QAM added
V3.0.10: EPSK added
Options:
R&S CMW-KM751 required for EPSK and QAM
Manual operation:
See
CONFigure:TDSCdma:MEAS<i>:UESignal:ECHannel:SICH
<SICHEnable>
Defines whether the uplink signal contains a shared information channel (HS-SICH, rela-
ted to a high speed downlink shared channel).
General Measurement Settings