Command Reference
R&S
®
CMW-KM750/-KM751
141
User Manual 1173.9670.02 ─ 05
<12_CarrFreqError> Carrier frequency error
Range:
-5000 Hz to 5000 Hz
Default unit: Hz
<13_UEpower>
User equipment power
Range:
-100 dBm to 35 dBm
Default unit: dBm
<14_PCDE>
Peak code domain error
Range:
-60 dB to 0 dB
Default unit: dB
<15_PCDECode>
Number of the code channel where the PCDE occurred
Range:
0 to 15
<16_WaveformQual>}Waveform quality
Range:
0 to 1
Example:
See
Usage:
Query only
Firmware/Software:
V3.0.10
Options:
R&S CMW-KM012
FETCh:TDSCdma:MEAS<i>:MEValuation:LIST:MODulation:AVERage?
FETCh:TDSCdma:MEAS<i>:MEValuation:LIST:MODulation:SDEViation?
Return average and standard deviation modulation single value results in list mode.
The values listed below in curly brackets {} are returned for the segments {...}
seg 1
, {...}
seg
2
, ..., {...}
seg n
, with n determined by
.
Return values:
<1_Reliability>
In list mode, a zero reliability indicator indicates that the results in
all measured segments are valid. A non-zero value indicates that
an error occurred in at least one of the measured segments.
{<2_SegReliability>
Reliability indicator for the segment. The meaning of the returned
values is the same as for the common reliability indicator, see
previous parameter.
<3_EVMRMS>
<4_EVMPeak>
Error vector magnitude RMS and peak value
Range:
0 % to 100 %
Default unit: %
<5_MagErrRMS>
<6_MagErrPeak>
Magnitude error RMS and peak value
Range:
0 % to 100 %
Default unit: %
Multi Evaluation Measurement Commands