Command Reference
R&S
®
CMW-KM645
39
User Manual 1173.9740.02 ─ 04
Parameters:
<ExpNomPwr>
The range of the expected nominal power can be calculated as
follows:
Range (Expected Nominal Power) = Range (Input Power) +
External Attenuation - User Margin
Range:
–55 dBm to +55 dBm for the input power at RF 1
COM and RF 2 COM (please notice also the range
quoted in the data sheet).
*RST:
0 dBm
Example:
See
Specifying General Measurement Settings
Firmware/Software:
V1.0.15.20
Manual operation:
See
CONFigure:FMSTereo:MEAS<i>:RFSettings:UMARgin
<UserMargin>
Sets the margin that the R&S
CMW adds to the expected nominal power in order to
determine its reference power. The reference power minus the external input attenua-
tion must be within the power range of the selected input connector; refer to the data
sheet.
Parameters:
<UserMargin>
Range:
0 dB to (55 dB + External Attenuation - Expected
Nominal Power)
*RST:
0 dB
Example:
See
Specifying General Measurement Settings
Firmware/Software:
V1.0.15.20
Manual operation:
See
CONFigure:FMSTereo:MEAS<i>:RFSettings:MLOFfset
<MLOffset>
Varies the input level of the mixer in the analyzer path.
Parameters:
<MLOffset>
Range:
-10 dB to 10 dB
*RST:
8 dB
Default unit: dB
Example:
See
Specifying General Measurement Settings
Firmware/Software:
V3.2.10
Manual operation:
See
CONFigure:FMSTereo:MEAS<i>:RFSettings:FOFFset
<FreqOffset>
Specifies a positive or negative frequency offset to be added to the carrier center fre-
quency (
CONFigure:FMSTereo:MEAS<i>:RFSettings:FREQuency
Signal Routing and Analyzer Settings
深圳德标仪器