CDMA2000 Signaling
R&S
®
CMW-KM8xx/-KS8xx
672
User Manual 1173.9511.02 ─ 12
CONFigure:CDMA:SIGN<i>:NETWork:PCHannel:RATE
<PagingChRate>
Sets the data rate of the forward paging channel.
Parameters:
<PagingChRate>
R4K8 | R9K6
*RST:
R9K6
Example:
See
Firmware/Software:
V1.0.15.0
Manual operation:
See
CONFigure:CDMA:SIGN<i>:NETWork:PCHannel:SCINdex?
Queries the current slot cycle index in use by both the MS and BS.
See also:
Return values:
<SlotCycleIndex>
Range:
0 to 7
*RST:
0
Example:
See
Usage:
Query only
Firmware/Software:
V1.0.15.0
Manual operation:
See
CONFigure:CDMA:SIGN<i>:NETWork:PCHannel:MSCindex
<MaxSlotCycIndex>
Sets the Paging Channel Max Slot Cycle Index. It defines an upper limit on the slot
cycle index allowed by the base station. The MS has an internally programmed prefer-
red slot cycle index, which is sent in the mobile's Registration message.
See also:
Parameters:
<MaxSlotCycIndex> Range:
0 to 7
*RST:
0
Example:
See
Firmware/Software:
V1.0.15.0
Manual operation:
See
CONFigure:CDMA:SIGN<i>:NETWork:PCHannel:BSCindex
<BroadSlotCIndex>
Specifies the interval of the periodical broadcast messaging. The value zero indicates
that periodic paging is disabled.
Command Reference