CDMA2000 Signaling
R&S
®
CMW-KM8xx/-KS8xx
590
User Manual 1173.9511.02 ─ 12
SENSe:CDMA:SIGN:RXQuality:RLP:ACK?
SENSe:CDMA:SIGN:RXQuality:RLP:SACK?
SENSe:CDMA:SIGN:RXQuality:RLP:BDATa?
SENSe:CDMA:SIGN:RXQuality:RLP:CDATa?
SENSe:CDMA:SIGN:RXQuality:RLP:DDATa?
SENSe:CDMA:SIGN:RXQuality:RLP:REASembly?
SENSe:CDMA:SIGN:RXQuality:RLP:BLANk?
SENSe:CDMA:SIGN:RXQuality:RLP:INValid?
SENSe:CDMA:SIGN:RXQuality:RLP:SUMMary?
SENSe:CDMA:SIGN:RXQuality:RLP:PPPTotal?
SENSe:CDMA:SIGN:RXQuality:RLP:DRATe?
4.4.4 RX Measurement: Pilot Strength
Pilot strength measurement is programmed as follows:
●
The application is controlled by SCPI commands with the following syn-
tax:
...:CDMA:SIGN:RXQuality:...
and the
token
...:PSTRength...
/
...:SFPower...
●
After a
*RST
, the measurement is switched off.
You can start the pilot strength measurement and retrieve the results using
READ:CDMA:SIGN:RXQuality:PSTRength
and
READ:CDMA:SIGN:RXQuality:SFPower?
.
The examples in this section focus on commands directly related to the test data mea-
surement. For general configuration of the signaling application refer to chapter
ter 4.4.1, "General Configuration"
4.4.4.1
Configuring the Measurement
// *****************************************************************************
// Configure RX measurement:
// continuous measurement, update rate.
// *****************************************************************************
CONFigure:CDMA:SIGN:RXQuality:PSTRength:REPetition CONT
CONFigure:CDMA:SIGN:RXQuality:PSTRength:URATe 2
4.4.4.2
Performing the Measurement
Set up a connection with the DUT.
// *****************************************************************************
// Start a single shot measurement and query the results.
// *****************************************************************************
INITiate:CDMA:SIGN:RXQuality:PSTRength
WHILE FETCh:CDMA:SIGN:RXQuality:PSTRength:STATe? <> "RDY"
FETCh:CDMA:SIGN:RXQuality:PSTRength?
FETCh:CDMA:SIGN:RXQuality:SFPower?
FETCh:CDMA:SIGN:RXQuality:PSTRength:STATe?
Programming