1xEV-DO Signaling
R&S
®
CMW-KM8xx/-KS8xx
54
User Manual 1173.9511.02 ─ 12
For further reference:
●
●
●
chapter 2.2.5, "External Fading"
●
chapter 2.2.6, "Internal Fading"
The individual scenarios are only offered for selection if the required software and
hardware options are available, as listed in the following table.
Table 2-7: Required hardware and software options
SU
U
TX I/Q Board
Software Options
"Standard Cell"
1
1
-
-
"Hybrid Mode"
1
1
-
KS888
"Standard Cell Fading, External"
1
1
B510x or B520x
-
"Standard Cell Fading, Internal"
1
1
B510F or B520F
KE100, KE800
All listed options are R&S CMW-... options. Example: B510F means R&S CMW-B510F
* Signal path is used by the both applications CDMA2000 1xRTT and CDMA2000 1xEV-DO
Remote command:
ROUTe:EVDO:SIGN<i>?
ROUTe:EVDO:SIGN<i>:SCENario?
ROUTe:EVDO:SIGN<i>:SCENario:SCELl
ROUTe:EVDO:SIGN<i>:SCENario:HMODe
ROUTe:EVDO:SIGN<i>:SCENario:SCFading:INTernal
ROUTe:EVDO:SIGN<i>:SCENario:SCFading[:EXTernal]
2.3.5 I/Q Settings
The parameters in this section configure the I/Q output and input paths for scenarios
with external fading.
In such scenarios, a connected R&S AMU200A superimposes fading on the baseband
forward link signal.
For a dual carrier scenario with external fading, all parameters described below are
available per carrier.
For general prerequisites, required options and background information see
GUI Reference