<17_WavQualMinP> Waveform quality at minimum power.
Range:
0 to 1
<18_OutOfTolCount> Out of tolerance result, i.e. percentage of measurement inter-
vals of the statistic count (see
limits, see
.
Range:
0 % to 100 %
Default unit: %
<19_CurStatCount>} Number of evaluated valid slots in this segment.
Range:
0 to 1000
Example:
See
Performing Single-Shot Measurements
Usage:
Query only
Firmware/Software:
V2.0.20
Options:
R&S CMW-KM012
For additional information concerning syntax elements and returned values refer to
Conventions and General Information
.
CALCulate:EVDO:MEAS<i>:MEValuation:LIST:CP:AVERage?
CALCulate:EVDO:MEAS<i>:MEValuation:LIST:CP:CURRent?
CALCulate:EVDO:MEAS<i>:MEValuation:LIST:CP:MINimum?
CALCulate:EVDO:MEAS<i>:MEValuation:LIST:CP:MAXimum?
FETCh:EVDO:MEAS<i>:MEValuation:LIST:CP:AVERage?
FETCh:EVDO:MEAS<i>:MEValuation:LIST:CP:CURRent?
FETCh:EVDO:MEAS<i>:MEValuation:LIST:CP:MINimum?
FETCh:EVDO:MEAS<i>:MEValuation:LIST:CP:MAXimum?
Returns the Channel Power (CP) value results in list mode. To define the statistical
length for
AVERage
,
MAXimum
,
MINimum
calculation and enable the calculation of the
results use the command
CONFigure:EVDO:MEAS<i>:MEValuation:LIST:
.
The values listed below in curly brackets {} are returned for each active segment:
{...}
seg 1
, {...}
seg 2
, ..., {...}
seg n
. The number of active segments n is determined by
CONFigure:EVDO:MEAS<i>:MEValuation:LIST:COUNt
.
The values described below are returned by
FETCh
and
READ
commands.
CALCulate
commands return limit check results instead, one value for each result listed below.
The number to the left of each result parameter is provided for easy identification of the
parameter position within the result array.
Return values:
<1_Reliabiltiy>
Conventions and General Information
. In list mode, a zero relia-
bility indicator indicates that the results in all measured seg-
ments are valid. A non-zero value indicates that an error occur-
red in at least one of the measured segments.