1xEV-DO Signaling
R&S
®
CMW-KM8xx/-KS8xx
219
User Manual 1173.9511.02 ─ 12
Manual operation:
See
For additional information concerning syntax elements and returned values refer to
Conventions and General Information
.
FETCh:EVDO:SIGN<i>:RXQuality:FLPFormance?
[<PacketSize>]
READ:EVDO:SIGN<i>:RXQuality:FLPFormance?
[<PacketSize>]
CALCulate:EVDO:SIGN<i>:RXQuality:FLPFormance?
[<PacketSize>]
Returns the results of the "Forward Link Performance" throughput measurement for the
specified packet size (and the selected carrier in multi-carrier scenarios), see
ter 2.2.14.5, "Forward Link Throughput Measurement"
The related carrier has to be pre-selected using the
command.
The values described below are returned by
FETCh
and
READ
commands.
CALCulate
commands return limit check results instead, one value for each result listed below.
Query parameters:
<PacketSize>
S128 | S256 | S512 | S1K | S2K | S3K | S4K | S5K | TOTal
This query parameter represents the physical layer packet size
for which the results shall be returned, i.e. it selects a row in the
"Forward Link Performance" result table. For instance, S1k
requests the results for a packet size of 1024 bits. If this param-
eter is omitted, the command returns the
TOTal
results, i.e. the
aggregates over all packet sizes.
Note that the "Composite" return values are aggregates over all
carriers
and
packet sizes, i.e. no matter which packet size is
specified, always the
TOTal
values are returned.
Return values:
<Reliability>
chapter 2.5.1.5, "Reliability Indicator"
<MACPackReceived> MAC Packets Received
Range:
0 or higher
*RST:
0
<PhyPacketSlots>
Physical Packet Slots
Range:
0 or higher
*RST:
0
<ThVsTestTime>
Throughput vs. Test Time
Range:
0 kbit/s or higher
*RST:
0 kbit/s
<ThVsTransmSlots> Throughput vs. Transmitted Slots
Range:
0 kbit/s or higher
<TestTime>
Test Time
Range:
0 to 10000
Default unit: no. of CDMA frames
Command Reference