1xEV-DO Signaling
R&S
®
CMW-KM8xx/-KS8xx
21
User Manual 1173.9511.02 ─ 12
–
1xEV-DO signaling extension module (R&S CMW-B230A)
●
One option CDMA2000
®
1xRTT basic signaling (R&S CMW-KS800)
●
One option CDMA2000
®
1xEV-DO basic signaling (R&S CMW-KS880)
●
One option CDMA2000
®
hybrid mode (R&S CMW-KS888)
Limitations
All available functionality is supported in CDMA signaling application.
In hybrid mode on a single SUU, 1xEV-DO signaling only supports Rev. 0/A. If Rev. B
is required to run in hybrid mode, the setup with two SUUs has to be chosen.
Setup Procedure in Hybrid Mode
1. Select scenario hybrid mode in both CDMA2000 and 1xEV-DO.
2. Configure both FWAs on different RF converters (e.g. CDMA2000 Sig on RF1
COM and 1xEV-DO Sig on RF3 COM).
3. Connect the DUT to the configured RF connectors using an external combiner.
4. Configure both signaling FWAs to the required RF frequencies and band classes.
5. Switch both CDMA2000 sig and 1xEV-DO sig on in any order.
As a result, CDMA2000 sig and 1xEV-DO sig should both be running and the
mobile should register in CDMA2000
®
1xRTT and open a session in CDMA2000
®
1xEV-DO.
2.2.4.4
Hybrid Mode on Two (or more) SUU
Hybrid mode using two SUUs is preferable in the following cases:
●
1xEV-DO Rev. B is required
●
One instrument doesn't offer a sufficient amount of RF paths, so the hybrid mode
has to be setup using two R&S
CMWs in a multibox scenario
Since version 3.0.11, if located in different R&S
CMWs, both master and slave SUU
may additionally run
. This allows to establish hybrid
mode with up to 2n cells on n CMWs.
Prerequisites
The minimum hardware and software configuration for hybrid mode using two SUUs
are:
●
Either
–
one R&S
CMW equipped with extra RF converter module (R&S CMW-B570B)
or
–
two R&S
CMWs and multibox synchronization equipment
and
General Description
深圳德标仪器