CMU-K20/-K21/-K22/-K23/-K24
Non Signalling Mode
1115.6088.12 2.7
E-10
Additional Information...
Alternative Settings
and Measurements
... on Step 1
#
Analyzer/Generator menu
The
Analyzer/Generator
menu contains three with associated
hotkeys used to
•
Define the RF input signal path and the trigger settings
(Analyzer Level)
•
Set the CMU RF analyzer
(Analyzer Settings)
and de-
termine the RF input signal that can be measured
•
Control the RF generator
(Generator)
and define the pa-
rameters of the RF output signal generated.
'
The
Analyzer/Generator
settings
are also provided in the
Analyzer
and
Generator
tabs of the
Con-
Softkeys and hotkeys
on
p.
2.11
.
The assignment between carrier frequency and channel
number is according to GSM specifications. As the CMU
simulates a base station, the generator signal corresponds to
the downlink (signal direction from the base station towards
the mobile station), the signal analyzed corresponds to the
uplink (signal direction from the mobile station towards the
base station). The channel/frequency assignment changes
accordingly.
The RF frequency can be set in multiples of 200 kHz. With an
additional
Frequency Offset
, an RF signal with an arbitrary
frequency that is in the range supported by the tester can be
generated and analyzed. In general, the RF generator level is
set to be different for the used timeslot and unused timeslots.
The level of the unused timeslots is defined relative to the
level in the used timeslot.
Selecting a definite training se-
quence (TSC) or bit modulation or
transmission mode in the
Genera-
tor Modulation
panel implies that
signals with these characteristics
are generated.
Selecting a definite TSC in the
Analyzer Settings
panel implies
that only signals with this TSC are
analyzed.
$
Measurement and Generator State
The state of the
Power/t Norm. GMSK
measurement is indi-
cated in the corresponding softkey (measurement control
softkey) and above the output fields for the results. The state
of the RF generator is indicated in the
Generator – RF Level
softkey.
For ongoing measurements, the results in the output fields
are constantly updated. All measured quantities refer to the
current burst. The default tolerance template for the power
ramp is defined according to GSM specifications. For various
reasons, an output field may fail to show a valid measure-
ment result (indication "---"):
•
The analyzer settings do not match the properties of the
input signal.
•
The input signal is missing.
•
The measurement is switched off
(OFF
is indicated in the
softkey controlling the measurement).
The current options for the meas-
urement status are
ON
(default)
and
OFF
. A third state,
HLT
, oc-
curs after a single-shot meas-
urement is terminated (see be-
low).
Once selected, the
Power
or
Modulation
measurement can be
switched off and on again by
means of the toggle key
ON/OFF
.
Generators may also be switched
on (state
ON)
and off (state
OFF)
by means of the
ON/OFF
key.
%
Max. Level
The autoranging mechanism adjusts the RF input path to the
applied signal. Alternatively, the expected signal level (for
GMSK-modulated GSM signals, the average RF input level
plus an appropriate margin of a few dB) can be set via Ana-
lyzer Level – RF Max. Level.
'
Chapter 4, p. 4.69 ff.
The permissible range
Max. Level
depends on the RF connector
and the external attenuation
used.
深圳德标仪器
135-1095-0799
Summary of Contents for CMU-K20
Page 4: ...深圳德标仪器 135 1095 0799 ...
Page 8: ...深圳德标仪器 135 1095 0799 ...
Page 10: ...深圳德标仪器 135 1095 0799 ...
Page 12: ...深圳德标仪器 135 1095 0799 ...
Page 18: ...深圳德标仪器 135 1095 0799 ...
Page 24: ...深圳德标仪器 135 1095 0799 ...
Page 26: ...深圳德标仪器 135 1095 0799 ...
Page 34: ...深圳德标仪器 135 1095 0799 ...
Page 58: ...深圳德标仪器 135 1095 0799 ...
Page 60: ...深圳德标仪器 135 1095 0799 ...
Page 78: ...深圳德标仪器 135 1095 0799 ...
Page 286: ...深圳德标仪器 135 1095 0799 ...
Page 288: ...深圳德标仪器 135 1095 0799 ...
Page 304: ...深圳德标仪器 135 1095 0799 ...
Page 632: ...深圳德标仪器 135 1095 0799 ...