Remote Control
R&S
®
NRT2
130
User Manual 1178.5550.02 ─ 04
Manual operation:
See
CALCulate<Measurement>[:CHANnel<Channel>]:NRT:PEP:HOLD:TIME
<value>
Specifies the hold time of the peak hold circuit. If the entry is valid, the
USER
mode is
automatically switched on and the default setting is switched off.
Suffix:
<Measurement>
.
1...100
<Channel>
1...2
Parameters:
<value>
Range:
1e-3 to 1e-1
*RST:
0.01
Default unit: s
Manual operation:
See
CALCulate<Measurement>[:CHANnel<Channel>]:NRT:VBWidth[:VALue]
<value>
Selects a certain video bandwidth filter (0..2). The actual filter bandwidth is sensor spe-
cific. For example [4 kHz, 200 kHz, 600 kHz] for NRT-Z14 or [4 kHz, 200 kHz, 4 MHz]
for NRT-Z43/-Z44.
Suffix:
<Measurement>
.
1...100
<Channel>
1...2
Parameters:
<value>
Range:
0 to 2
*RST:
2
Manual operation:
See
CALCulate<Measurement>:LIMit[:STATe]
<state>
These commands are used to start (ON) or stop (OFF) the search for the min/max val-
ues, which cover the measurement functions set under subsystem SENSE<n>: FUNC-
tion [:ON] <measurement function>. The min/max memories are automatically reset
upon start. During a search for the max/min values, the value set under subsystem
CALCulate<n>:LIMit:TYPE (maximum, minimum or the difference thereof) is returned
to a request for data, not however the currently measured value. The request for data
is in the form of the query SENSE<n>: DATA?.
Suffix:
<Measurement>
.
1...100
Parameters:
<state>
ON | OFF
*RST:
OFF
Example:
CALC1:LIM ON
CALCulate