Remote Control Commands
R&S
®
NRX
284
User Manual 1178.5566.02 ─ 08
DISPlay[:WINDow<Window>]:TRACe:MARKer<Undef>:SELection
<markerNo>
Shows the selected marker in the trace.
Suffix:
<Window>
.
1 to 4
Measurement pane
<Undef>
1 to n
No suffix required.
Parameters:
<markerNo>
NONE | M1 | M2 | M3 | M4
*RST:
NONE
Manual operation:
See
14.6.8
Pulse Analysis
Further information:
●
[SENSe<Sensor>:]TRACe:MEASurement[:STATe]
............................................................ 285
[SENSe<Sensor>:]TRACe:MEASurement:AUTO[:STATe]
...................................................285
[SENSe<Sensor>:]TRACe:MEASurement:OFFSet:TIME
................................................... 286
[SENSe<Sensor>:]TRACe:MID:OFFSet:TIME
...................................................................286
[SENSe<Sensor>:]TRACe:MID:TIME
...............................................................................286
CALCulate<Measurement>:TRACe:MEASurement:ALGorithm
........................................... 287
CALCulate<Measurement>:TRACe:MEASurement:DEFine:DURation:REFerence
CALCulate<Measurement>:TRACe:MEASurement:DEFine:TRANsition:HREFerence
CALCulate<Measurement>:TRACe:MEASurement:DEFine:TRANsition:LREFerence
CALCulate<Measurement>:TRACe:MEASurement:POWer:AVG?
.......................................288
CALCulate<Measurement>:TRACe:MEASurement:POWer:HREFerence?
...........................288
CALCulate<Measurement>:TRACe:MEASurement:POWer:LREFerence?
........................... 289
CALCulate<Measurement>:TRACe:MEASurement:POWer:MAX?
...................................... 289
CALCulate<Measurement>:TRACe:MEASurement:POWer:MIN?
....................................... 289
CALCulate<Measurement>:TRACe:MEASurement:POWer:PULSe:BASE?
CALCulate<Measurement>:TRACe:MEASurement:POWer:PULSe:TOP?
............................290
CALCulate<Measurement>:TRACe:MEASurement:POWer:REFerence?
............................. 290
CALCulate<Measurement>:TRACe:MEASurement:PULSe:DCYCle?
.................................. 290
CALCulate<Measurement>:TRACe:MEASurement:PULSe:DURation?
................................290
CALCulate<Measurement>:TRACe:MEASurement:PULSe:PERiod?
...................................291
CALCulate<Measurement>:TRACe:MEASurement:PULSe:SEParation?
............................. 291
CALCulate<Measurement>:TRACe:MEASurement:TRANsition:NEGative:DURation?
CALCulate<Measurement>:TRACe:MEASurement:TRANsition:NEGative:OCCurrence?
CALCulate<Measurement>:TRACe:MEASurement:TRANsition:NEGative:OVERshoot?
CALCulate<Measurement>:TRACe:MEASurement:TRANsition:POSitive:DURation?
CALCulate<Measurement>:TRACe:MEASurement:TRANsition:POSitive:OCCurrence?
CALCulate<Measurement>:TRACe:MEASurement:TRANsition:POSitive:OVERshoot?
CALCulate<Measurement>:TRACe:MEASurement:TRANsition:SPERiod?
.......................... 293
DISPlay[:WINDow<Window>]:TRACe:MEASurement:POWer:AVG[:STATe]
Measurement Settings and Results
www.allice.de
Allice Messtechnik GmbH