Remote Commands
R&S
®
Spectrum Rider FPH
429
User Manual 1321.1011.02 ─ 11
[SENSe:]CHANnel<1...3>
<ChannelNumber>
This command selects the channel to be analyzed.
You have to set the frequency mode with
The numeric suffix at CHANnel is irrelevant for this command.
Parameters:
<ChannelNumber>
Numeric value that selects the number of the channel to be ana-
lyzed.
*RST:
Depends on the channel table.
Example:
See
[SENSe:]CHANnel:TABLe:SELect<1...4>
[SENSe:]FREQuency:CENTer
<CenterFrequency>
This command defines the center frequency of the R&S Spectrum Rider.
In spectrum analyzer mode, the command also defines the measuring frequency for
time domain measurements (span
=
0).
Parameters:
<CenterFrequency> Range:
Depends on the operating mode and is specified in
the data sheet.
*RST:
fmax /2 with fmax = maximum frequency
Default unit: MHz
Example:
FREQ:CENT 100MHz
Defines a center frequency of 100 MHz.
[SENSe:]FREQuency:CENTer:STEP
<Stepsize>
This command defines the center frequency step size.
Parameters:
<Stepsize>
Range:
1 Hz to fmax
*RST:
- (AUTO 0.1*SPAN is switched on)
Default unit: MHz
Example:
FREQ:CENT:STEP 120MHz
Defines a CF step size of 120 MHz.
[SENSe:]FREQuency:INPut:MODE<1..3>
<InputMode>
This command selects the frequency mode. Select the Channel frequency mode only if
you want to work with channel tables. In this case, the input of the center frequency is
not a frequency value, but a channel number.
The numeric suffix at MODE is irrelevant for this command.
Remote Control - Commands