Remote Commands
R&S
®
Spectrum Rider FPH
419
User Manual 1321.1011.02 ─ 11
Prerequisites for this command: Select FSK demodulation
The numeric suffix at CALCulate is irrelevant for this command.
Suffix:
<1...2>
.
1...2
Parameters:
<Frequency>>
<numeric value>
Default unit: Hz
Example:
CALC:MARK:FUNC:DDEM:MDEV?
Query frequency deviation.
Usage:
Query only
CALCulate<1...2>:MARKer:FUNCtion:DDEMod:MERRor[:RESult]?
This command queries the magnitude error of the measured signal.
Prerequisites for this command: Select FSK demodulation
The numeric suffix at CALCulate is irrelevant for this command.
Suffix:
<1...2>
.
1...2
Parameters:
<MagnitudeError>
<numeric value>
Default unit: PCT
Example:
CALC:MARK:FUNC:DDEM:MERR?
Query magnitude error.
Usage:
Query only
CALCulate<1...2>:MARKer:FUNCtion:DDEMod:MINDex[:RESult]?
This command queries the modulation index of the measured signal.
Prerequisites for this command: Select ASK demodulation
The numeric suffix at CALCulate is irrelevant for this command.
Suffix:
<1...2>
.
1...2
Parameters:
<ModIndex>
<numeric value>
Default unit: PCT
Example:
CALC:MARK:FUNC:DDEM:MIND?
Query modulation index.
Remote Control - Commands
www.allice.de
Allice Messtechnik GmbH