Remote Commands
R&S
®
Spectrum Rider FPH
368
User Manual 1321.1011.02 ─ 11
= 10 log
10
( (4
π
df / c)
2
)
= 20 log
10
(d) + 20 log
10
(f) + 20 log
10
( 4
π
/c )
= 20 log
10
(d) + 20 log
10
(f) - 147.55
Example:
EIRP:PLOS?
-> 38.00
Return the free space path loss of 38.00 dB.
Usage:
Query only
[SENSe:]EIRPpower:POWer?
This command queries the EIRP power measurement.
EIRP
dB
= Measured channel power (excluding antenna gain and cable loss) - received
antenna gain + received cable loss + FSPL
dB
Example:
EIRP:POW?
-> -39.35
Return the EIRP power measurement of -39.35 dB.
Usage:
Query only
[SENSe:]EIRPpower:RAGain
<EIRPAntennaGain>
This command input antenna gain value in dB and value is displayed in dBi on the
EIRP info bar.
Parameters:
<EIRPAntennaGain> Numeric value that defines the antenna gain.
Default unit: dB
[SENSe:]EIRPpower:SUM?
Return the sum of EIRP power (dBm) for horizontal and vertical of the dual polarization
measurement.
Usage:
Query only
DISPlay<1...2>:EIRP:HORizontal
This command dispalys the ERIP power of the horizontal polorization.
The numeric suffix at DISPlay is irrelevant for this command.
Suffix:
<1...2>
.
1...2
Usage:
Event
DISPlay<1...2>:EIRP:MAXHold:RESet
This command performs a reset on the maximum hold function.
Remote Control - Commands
www.allice.de