Figure 7-2: Screen layout of the directional power mode
1 = Selected transmission standard
2 = Connected power sensor model
3 = Reference for relative power measurements
4 = Power offset
5 = Readout of the forward power
6 = Analog readout of the forward power
7 = Readout of the matching value
8 = Analog readout of the matching value
9 = Measurement frequency
10 = Configuration overview icon
11 = Directional power sensor "MEAS" softkey menu
7.2.1
Connecting a Directional Power Sensor
The R&S Spectrum Rider controls and powers the directional power sensors via a spe-
cial interface on the top of the instrument.
Connect the power sensor cable via the USB to binder adapter to the USB port of R&S
Spectrum Rider. The power sensor itself is located between the source and the load of
the test setup.
For the test setup of the directional power sensor, see
If the R&S Spectrum Rider recognizes a power sensor, it sets up a connection via the
interface and after a few seconds shows the results. It displays the type of the power
sensor in the display header. If an error occurs, the R&S Spectrum Rider shows a cor-
responding message.
Chapter 7.1.1, "Connecting a Power Sensor"
Using a Directional Power Sensor