Spectrum Analyzer Mode
R&S
®
Spectrum Rider FPH
196
User Manual 1321.1011.02 ─ 11
1 =
2 = Marker (solid line)
3 = Delta marker (dotted line)
4 = Active marker label (see highlighted line on the marker list as well as the marker label )
5 = Marker label: M(x)
6 = Delta marker label: D(x)
7 = Marker input field
8 = Marker menu
6.2.7.2
Positioning Markers
1. Press [MARKER] key.
The marker menu opens.
If no marker has been activated, the R&S Spectrum Rider automatically activates
the main marker and positions it on the maximum level that has been measured. In
addition, the marker frequency input field opens.
You can perform the following actions:
● Position the marker with the rotary knob
When positioning the marker with the rotary knob, the step size is one pixel.
● Enter a marker position with the number keys and confirm the entry with one of
the unit keys.
2. Confirm the marker position by pressing the rotary knob.
The
shows the horizontal position of all markers and the
corresponding vertical value. You can select any marker in the
for further marker function using the marker softkey menu. You can
also use rotary knob to select any of the markers displayed in the
Special touchscreen gesture
Alternatively, double tap on the touchscreen to position the marker on the trace win-
dow. The first marker that is positioned on the trace window is the main marker, the
following markers added on the trace window are the delta markers.
See
6.2.7.3
Positioning a Delta Marker
When a normal marker is already in use, you can add delta markers.
1. Press [MARKER] key.
The marker menu opens.
2. Select "New Marker" softkey.
The R&S Spectrum Rider activates a delta marker and positions it on the next max-
imum level that has been measured. In addition, the delta marker input field opens.