Spectrum Analyzer Mode
R&S
®
Spectrum Rider FPH
134
User Manual 1321.1011.02 ─ 11
Figure 6-3: Screen layout for TDMA power measurements
1 = TDMA power measurements mode
2 = TDMA power
3 = Measurement standard
4 = Measurement time
5 = Measurement limits
6 = Trigger level
7 = Trigger delay
8 = =Measurement time entry input
9 =
10 =
11 = TDMA power measurement softkey
6.1.4.1
Selecting a Standard
For more information on selecting a standard, see
Chapter 6.1.3.1, "Selecting a Stan-
6.1.4.2
Setting the Burst Length
The burst length is the measurement time that the R&S Spectrum Rider used to per-
form the TDMA power measurement. The burst length can be equal or less than the
sweep time.
1. Press [MEAS] key.
2. Select "Burst Length" softkey.
The R&S Spectrum Rider opens an input field to define the burst length.
3. Enter the length of the burst you need.
Performing Spectrum Measurements
www.allice.de
Allice Messtechnik GmbH