Preface
R&S
®
FSVA/FSV
11
Quick Start Guide 1321.3066.02 ─ 06
– Mixer settings for each band are saved and maintained even after preset-
ting the instrument; they can be preset explicitly using the "Preset Band"
function
– If a second range (harmonic) is available, it can be activated and defined
freely, also for standard bands
– When using two ranges for a band, the handover frequency can be defined
freely within the overlapping frequency range, also for standard bands
– Additional traces are available for use when using the signal identification
functions Signal ID and Auto ID
– All available conversion loss tables are offered for selection; validity tests
are performed after selection
1.5
Notes for Users of R&S
FSV 1307.9002Kxx Mod-
els
Users of R&S
FSV 1307.9002Kxx models should consider the following differen-
ces to the description of the newer R&S
FSVA/FSV 1321.3008Kxx models:
●
Functions that are based on the Windows
10 operating system (e.g. printing
or setting up networks) may have a slightly different appearance or require dif-
ferent settings on the Windows XP based models. For such functions, refer to
the Windows documentation or the documentation originally provided with the
R&S
FSV instrument.
●
The R&S
FSV 1307.9002K03 model is restricted to a maximum frequency of
3
GHz, whereas the R&S
FSVA/FSV1321.3008K04 model has a maximum
frequency of 4
GHz.
●
The bandwidth extension option R&S
FSV-B160 (1311.2015.xx) is not availa-
ble for the R&S
FSV 1307.9002Kxx models. The maximum usable I/Q analy-
sis bandwidth for these models is 28
MHz, or with option R&S
FSV-B70,
40
MHz.
Notes for Users of R&S
FSV 1307.9002Kxx Models